4

The simplest method will be a multi-step approach. The first step will be a defective product detection, that gathers general data about the product stream and quarantines defective products. On a parallel path, a small batch of samples will be also sequestered from the main line to be analyzed continuously for detectable defects. A laboratory analysis ...


1

For anyone coming later: I ended up using a procedure described here: Kevin C. Gross, Phenomenological model for IR emission from high explosive detonation fireballs In one sentence: I ended up measuring the blackbody spectrum at increasing temperatures. Then fitting a linear relation between measured and theoretical value for emission intensity (per ...


1

It's more than merely a question of absolute max and min. I recommend you read Bevington's "Data Reduction and Error Analysis" as a good, simple start. Precision can only be estimated based on the statistics of your data, and that depends on your entire setup: temporal and spatial uniformity of the light source, for example. First, calculate the mean ...