I am working on some calculation for an LCA of a plant. The plant has provided me a report that an engineering firm has measured the emissions from the stack. I am trying to estimate the amount of CO<sub>2</sub> produced per year. 

The total volume of gas emitted was 2.08Rm3 (25 degrees C, and 101.3 kPa) every two hours. The gas contains 1.30% CO<sub>2</sub>. and the plant runs 1450 hours/year. 

I tried to find the density of CO<sub>2</sub>, which is 1.78g/L and multiplied volume (1,508,000 L/year) by (0.013) but I am unsure if this is correct. 

The plant is using wood chips in a suspension burner and undergoing complete combustion. But in their report there is 10.40000 kg of carbon monoxide being produced.